Project

General

Profile

Actions

Bug #4683

open

properly report OM2000 bring-up problems

Added by laforge over 3 years ago.

Status:
New
Priority:
Normal
Assignee:
Category:
Ericsson BTS
Target version:
-
Start date:
07/30/2020
Due date:
% Done:

0%

Spec Reference:

Description

If there is a mismatch between hardware or IDB configuration and the osmo-bsc configuration, the OM2000 bring-up will fail in various ways. This is not clearly visible at the moment, and in many situations the user will not be aware that anything has been going wrong. In some situations RSL will simply never be initialized successfully - in some other situations even RSL comes up without errors, but the RBS simpyl doesn't transmit.

The most important indications we get from the RBS:
  • some Enable Result, particularly on the TX or TRXC, not according to request, optionally with information which IE is causing the problem
  • Failure Maps
Let's make sure that
  • the related errors are logged at ERROR level (in human-readable form)
  • the state of the MO is easily available via introspection/VTY
  • we document how to deal with this in the user manual or wiki

Related issues

Related to OsmoBSC - Feature #4514: OM2000 Support for Ericsson RBS6000 / DUG 20Resolvedtnt04/27/2020

Actions
Related to OsmoBSC - Bug #6378: Ericsson DUG 20 rejects SI2quaterNewkeith02/28/2024

Actions
Actions #1

Updated by laforge over 3 years ago

  • Related to Feature #4514: OM2000 Support for Ericsson RBS6000 / DUG 20 added
Actions #2

Updated by keith about 2 months ago

  • Related to Bug #6378: Ericsson DUG 20 rejects SI2quater added
Actions

Also available in: Atom PDF

Add picture from clipboard (Maximum size: 48.8 MB)